You may not obliterate or alter another entry. Reference FAR 43.9, .11.

If the A&P did not perform or supervise the work being done, he has no entry to make.

Sorry but "atrocious" is not a reason to alter or explain an entry. If anything, insert a copy of the work order in the maintenance records, but technically if its not in the logs, it didn't happen.
Reply With Quote
  #2  
Unread 09-29-08, 08:44 PM
Ernie Martin's Avatar
Ernie Martin Ernie Martin is offline
Administrator
 
Join Date: Apr 2002
Location: Miami, Florida
Posts: 990
Ernie Martin is an unknown quantity at this point
Thanks for the response. However, it's the A&P who performed the work who is being asked, essentially, to clarify his unintelligible entry. I get that he can't obliterate or alter his own earlier entry, but can he make a second clarifying entry? BTW, there is no work order: the A&P knew of the squawk, diagnosed the problem, fixed it, and made the entry in question.

Ernie
Reply With Quote
  #3  
Unread 09-29-08, 09:20 PM
tropical tropical is offline
Registered User
 
Join Date: Oct 2006
Location: Florida
Posts: 146
tropical is an unknown quantity at this point
Quote:
Originally Posted by Ernie Martin View Post
Thanks for the response. However, it's the A&P who performed the work who is being asked, essentially, to clarify his unintelligible entry. I get that he can't obliterate or alter his own earlier entry, but can he make a second clarifying entry? BTW, there is no work order: the A&P knew of the squawk, diagnosed the problem, fixed it, and made the entry in question.

Ernie
He can make the second entry, but do not obliterate the original. FWIW, if you make an erroneous entry in a log, the correct way is to draw a single line through the entry, then make an entry that it was entered in error and sign.

tropical
A&P/IA
Reply With Quote
Reply



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is Off
HTML code is Off
Forum Jump


All times are GMT -4. The time now is 09:29 AM.


Powered by vBulletin® Version 3.6.9
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.