It is confusing, but I think I understand what Herb is saying.
The AD covers two items: Spars CAPS and spar WEBS. P-models are only affected by the spar CAP AD up to serial P3370138 - this would include all the P337G models. The P337H models are exempt by serial number. The spar WEB portion of the AD applies to all P-model UP TO P3370313. After that serial, they are exempt. So some P337H airframes are 100% exempt from this AD, while other are only affected only by the WEB inspection. Covered P-model S/Ns must have 10000 hours TTAF before the AD becomes effective, then re-inspect every 500 hours. Is this clear as mud? Last edited by mshac : 10-22-20 at 12:33 PM. |
#2
|
||||
|
||||
AD78-09-05 shop recommendation
So if I’m reading this correctly a 336 has 5000 hours until compliance with the AD?
|
#3
|
||||
|
||||
Yes, unless regularly flown below 1500' AGL (think firefighting) then 3000 hrs.
|