Thanks Ernie...I did read the entire thread and I was aware of your heartache over this issue. I agree that I certainly do not require super accurate readings to know how much fuel is on board but it does make for a nice cross check. I suppose more importantly, fuel gages would be my only line of defense should I spring a leak during flight and fuel was exiting the wings without going through the engines. My problem appears to be in the aforementioned fuel control monitor, C668004-0102. My gages indicate quite accurately when they receive electricity but it seems to be an all or nothing affair. If you wiggle the connection on the box, the gages come back to life. Jeff Axel has given me a lead on a possible repair facility to fix my existing box so I'll see where that leads in the morning. Thanks! Ed