  #7  
Unread 10-23-19, 03:00 PM
n86121's Avatar
n86121 n86121 is offline
bigcheese
 
Join Date: Nov 2003
Location: Potomac Airfield~!
Posts: 349
n86121 is on a distinguished road
Updated rear cowl drain map

I think I have them all traced correctly now.
Believe it or not, many transition to firesleeved hoses so it is a bit confusing!
Retracing a bowl of red spaghetti backwards from each end.

When mixture in detent. Cleanly shuts idle.
Is definitely in full idle against the stop.

Doesn't drip immediately on shut down, takes a while before ...drip drip drip.

Drip from LR cylinders definitely stops w fuel closed overhead.

Still drops with newly overhauled flow divider from QAA.COM.
Still drips after a while, and then endlessly.
Flow divider spec only supposed to hold 1 PSI for 2 mins.

Thinking what else could be seeping fuel into cylinders, ...I thought of hand primers...?

Noted from your comments,
I discovered (after 25 years) that hand primers have a lock position.
I have used them so rarely, I never noted the actual detent position before.
Generally I'd just push them in and twist, but apparently not locked.

Fuel back on.
We will see if drip resumes with primer in detent.
Attached Images
File Type: jpg rear engine drains.jpg (987.7 KB, 2048 views)
__________________
David Wartofsky
Potomac Airfield
10300 Glen Way
Fort Washington, MD 20744
Reply With Quote
 



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is Off
HTML code is Off
Forum Jump


All times are GMT -4. The time now is 12:01 AM.


Powered by vBulletin® Version 3.6.9
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.