CHT Probe

Dear Sir,
IO-360A on the 336. The Cylinders are the same though. I agree with matching the probe to the gauge, BUT, it is a lot easier and cheaper to just calibrate the system as a whole once the probe is replaced. Not a bad idea anyway, who knows when or if it was last done.
Regards,
James
Reply With Quote
  #2  
Unread 01-24-11, 05:05 PM
Mark Hislop Mark Hislop is offline
Registered User
 
Join Date: May 2002
Location: Aurora, IL (ARR)
Posts: 171
Mark Hislop is an unknown quantity at this point
Contact Paul Malkasian at http://www.fuelsenders.com/ . He might be able to repair yours, or tell you where to find one. He is extremely knowledgeable.
__________________
Mark Hislop
N37E
Reply With Quote
  #3  
Unread 01-27-11, 02:18 PM
J.T.Grant J.T.Grant is offline
Registered User
 
Join Date: Jul 2004
Location: Huntsville AL KMDQ
Posts: 53
J.T.Grant is an unknown quantity at this point
CHT Probe

Dear Sirs,
thanks to all for your help. Problem solved. Good CHT readings again.
One day all the old gauges will come out and something new and shiny will go in their place.
Until then, what has been good for the last 47 years should continue to do the job.
Thanks again.
James
Reply With Quote
Reply



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is Off
HTML code is Off
Forum Jump


All times are GMT -4. The time now is 07:39 AM.


Powered by vBulletin® Version 3.6.9
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.