Ditto. I had fuel seeping from one tank to the other. Valve wasn’t providing positive shut off of tanks. I also couldn’t get shut off during fuel strainer servicing. You can try draining your fuel strainer with valve in off position. If it continues to dribble, absolutely your valve is not closing off a tank. I’ve posted here how to rebuild valve. I’m an E model with main and aux tanks. The G and later models have simplified fuel system. I might guess the valve made by same people? And therefore what I posted applies to those as well. Could never find anyone who would service them.