JAG,

I removed the check valve yesterday afternoon and found the flow was correct and that it was clean, but would not hold back pressure. To test the valve, I covered the weep holes, blew through it and it leaked so I dissembled it and found the neoprene seal on the disc was cracked in several places. Yuengling has them in stock so I placed an order for 2 new valves and expect them tomorrow.

Thank you for the help.