Good evening:

You can't like any of that. It sounds like the front engine system is the closest to normal. I would adjust the front regulator to 28.4V. Once it's set there let's see how it handles the load. We also want to see a steady amp meter. If the amp meter is waving at you there is a problem in the field circuit. Let me know what you get and we will diagnose.

One step at a time will win the battle.

Report your findings.
Reply With Quote
  #2  
Unread 09-10-20, 07:57 AM
patrolpilot's Avatar
patrolpilot patrolpilot is offline
Registered User
 
Join Date: Sep 2019
Location: South Texas
Posts: 312
patrolpilot is on a distinguished road
Interesting and timely topic. I recently experienced a significant electrical event after takeoff; I thought I had documented it here but didn't and will add that topic today.

I wanted to mention that as the troubles were corrected, the amp meter continued to have a "hard, full-range cycle. On the ramp, I ran through the Electrical System Ops Check outlined in the POH, and at the end of the successful test, I realized that my amp meter indication had returned to the regular, light, small bumping on the meter.

My battery pack did not pass the Alternator Restart Test, so the batteries are being replaced now while the airplane is in maintenance. I found and purchased the SK337-46A Battery Pack Kit recently. Given what happened to my airplane, my mechanic might replace the existing pack with the kit.

As pilots, we are supposed to perform both the Electrical System Ops Test and Alternator Restart Test at 25-hour intervals. I remember this from attending Cessna Skymaster school in January '78. While in the airplane, the paragraph format in the Manual is tough to follow. I listed them out in checklist form in ForeFlight and also kept it as a document within the app (attached).

From experience, when you push on either electrical test button, push with a clockwise movement on the button. The button is thread onto the shaft of the switch, that shaft is free to rotate. It is impossible to get them too tight, but I have found them missing and on the airplane floor. I haven't experienced the loss since I started adding the rotation with the push.
Attached Images
File Type: jpg SK337-46A.jpg (22.3 KB, 715 views)
Attached Files
File Type: pdf Electrical System Test Checklists_REV 1.pdf (24.0 KB, 747 views)
Reply With Quote
  #3  
Unread 09-10-20, 02:38 PM
DrDave DrDave is offline
Registered User
 
Join Date: Nov 2010
Location: Seattle
Posts: 115
DrDave is on a distinguished road
Does the regular, small, bumping of the amp meter correspond to any known electrical load?

Dave
Reply With Quote
  #4  
Unread 09-10-20, 11:50 PM
Learjetter's Avatar
Learjetter Learjetter is offline
Registered User
 
Join Date: Jun 2010
Location: KOKC
Posts: 244
Learjetter is on a distinguished road
Exasperating

Quote:
Originally Posted by DrDave View Post
Good evening:

You can't like any of that. It sounds like the front engine system is the closest to normal. I would adjust the front regulator to 28.4V. Once it's set there let's see how it handles the load. We also want to see a steady amp meter. If the amp meter is waving at you there is a problem in the field circuit. Let me know what you get and we will diagnose.

One step at a time will win the battle.

Report your findings.
Rear alt field circuit to case= 15 ohms. Book value 10-12 ohms. Good diode test on real alternator.. Haven’t check front yet. Forgot about AC volt test, again.

Ran engines separately and adjusted both VR to 28.0v
Running both engines together showed 27.9-28.1v fairly steady, even with a load of full lights. Annunciators appeared to operate normally....but...rear alt out light would blink occasionally. Looking closely at warning board, we determined terminals 1&2 and 6&7 were wired backwards, with terminal 2&6 to cathodes instead of 1&7. Fixed that, re-ran front engine and it shows 30v. Gave up and came home to some 12 year old Glenfiddich and read old Tom Carr posts in the CPA forum.

I think I need to start over, but none of the troubleshooting guides in the service manual match these symptoms.
Reply With Quote
  #5  
Unread 09-11-20, 04:43 PM
Kim Geyer Kim Geyer is offline
Registered User
 
Join Date: May 2002
Location: Bahama, NC
Posts: 291
Kim Geyer is an unknown quantity at this point
don't forget to look at the trip out sensor.
had 2 of our 337s doing stupid electrical stuff and found the sensor had corroded pins.
re pinned the connector and everything good. The other one I replaced the sensor. Its located on the copilots side of the pedestal. little rectangle box about the size of a pack of smokes.
Reply With Quote
  #6  
Unread 09-11-20, 08:53 PM
Learjetter's Avatar
Learjetter Learjetter is offline
Registered User
 
Join Date: Jun 2010
Location: KOKC
Posts: 244
Learjetter is on a distinguished road
Eureka!

Turns out, the wiring diagrams in the Service manual depict the printed circuit board in two places. In one drawing, it shows the circuit one way, and in another, it shows it differently.

When I ignore the drawing on page 4-3, and wired the board as in 4_2_1, magically, the system works. Annunciator lights come on when the switch is off. Adjusted each regulator to 28.0v to give 27.7v (book value with load on). And it all worked. Test flight soon to confirm.

Still have a jittery ammeter, but at this point, I'm willing to live with it until annual when we bring this airplane into the 21st century and install plane power R1224s and an EI Voltmeter/ammeter and pile all the ancient diodes and resistors and capacitors in the middle of the ramp and set fire to them.

That is, if I can convince the local FSDO to play ball and sign off my 337 form.
Attached Images
File Type: jpg Alternator Warning Board 4_2_1.jpg (309.4 KB, 588 views)
File Type: jpg Alternator Warning Board 4_3.jpg (321.7 KB, 581 views)
Reply With Quote
Reply



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is Off
HTML code is Off
Forum Jump


All times are GMT -4. The time now is 04:26 AM.


Powered by vBulletin® Version 3.6.9
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.