Skymaster Forum  

Go Back   Skymaster Forum > Messages
Register FAQ Members List Calendar Today's Posts

Reply
 
Thread Tools Rate Thread Display Modes
  #1  
Unread 12-01-11, 09:58 PM
edasmus edasmus is offline
Registered User
 
Join Date: Nov 2006
Location: ARR - Aurora, IL - USA
Posts: 420
edasmus is on a distinguished road
Send a message via AIM to edasmus
Plug was replaced today with a new one. It even tested bad this time which I was happy to see.

Thanks for the help Walter.

Ed
Reply With Quote
  #2  
Unread 12-02-11, 10:48 AM
Walter Atkinson Walter Atkinson is offline
Registered User
 
Join Date: Mar 2005
Location: Vail, Colorado
Posts: 95
Walter Atkinson is an unknown quantity at this point
Quote:
Originally Posted by edasmus View Post
Plug was replaced today with a new one. It even tested bad this time which I was happy to see.

Thanks for the help Walter.

Ed
Any time. Remember that the best way to test an ignition system is during an in-flight, high power LOP mag check. Weak plugs will show themselves very early on. Change 'em before they interfere with your family trip to grandma's house!
__________________
Walter Atkinson
Advanced Pilot Seminars
Reply With Quote
  #3  
Unread 12-02-11, 04:38 PM
edasmus edasmus is offline
Registered User
 
Join Date: Nov 2006
Location: ARR - Aurora, IL - USA
Posts: 420
edasmus is on a distinguished road
Send a message via AIM to edasmus
Yep....this one was caught on my usual in flight mag checks. Ground run was fine before take-off. 15 min later at 9,500 feet, the plug was just along for the ride. )
Reply With Quote
Reply



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is Off
HTML code is Off
Forum Jump


All times are GMT -4. The time now is 01:04 PM.